CVE-2025-64307EPSS p13.9%

CVE-2025-64307CVE-2025-64307

Description

The Brightpick Internal Logic Control web interface is accessible without requiring user authentication. An unauthorized user could exploit this interface to manipulate robot control functions, including initiating or halting runners, assigning jobs, clearing stations, and deploying storage totes.

Scoring

CVSS 6.5 ()
VectorCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
EPSS0.23% probability of exploitation · percentile 13.9% · 2026-08-11T12:00:17Z
Last modified2026-06-25
Sourced from NVD + FIRST.org EPSS. Curated for EU compliance use cases by Adam Lundqvist, Founder at SQUR.