CVE-2019-18336EPSS p73.8%
CVE-2019-18336CVE-2019-18336
siemens / simatic_s7-300_cpu_firmware
Description
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
Scoring
| CVSS | 7.5 () |
| Vector | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
| EPSS | 1.67% probability of exploitation · percentile 73.8% · 2026-06-19T12:03:05Z |
| Last modified | 2026-06-02 |
Related by meaning· 6